Answer: Yes, the index boundaries MDET, MLIG, MVAR, MAOP, MOCS and MEEX can be adapted if necessary, they have the following meanings:
Adaptation is done by changing all PARAMETER statements in the source code that contain one of these constants. MDET is of special importance since the two-dimensional arrays HR, HI, VR und VI that are declared in routine calc.f cause with MDET*MDET*32 Byte the largest part of the memory requirements of AOMX. Dependent on the number of electrons, the following MDET values are required at minimum: